Phone:0086-371-60922096

10Ton Coal Fired Steam Boiler

10Ton Coal Fired Steam Boiler

Gas-fired 10ton coal fired steam boiler principle gas steam boiler with natural gas, liquefied petroleum gas, fuel gas such as city gas as fuel, the combustion in the furnace heat put out by heating the pot water, and which is vaporized into steam energy conversion device. Water pan (drum) is continuously released from the combustion of a gaseous fuel energy to heat the furnace, raising the temperature and generating steam under pressure, since the boiling point of water with elevated pressure is raised, the pot is sealed, the water vapor inside the expansion pressure is generated is limited thermodynamic form (strictly speaking, water vapor in the boiler water is heated to a constant-pressure steam drum regasified saturated formed) is widely used as an energy source. Boiler and boiler shell consists of two main furnace and ensure accessories, ancillary equipment instrumentation, control and protection system safe and economic operation of its continuous constituted. This boiler is a boiler drum with a water cooling wall at about the subregional arrangements drum pyrotechnic two return pipe, before the folded portion of the drum front smoke box. Between the drum and the tank in connection with the downcomer tubes and water-cooled bi, constituting the frame of the combustion chamber. There upper steam separator drum to reduce the water vapor out of the tape. Pan heating surface of a lower portion of the drum, and the water cooling pipe bi pyrotechnic tube. The basic components of a steam boiler and a steam boiler operating principle is constituted by a series of devices can be roughly divided into two main parts and auxiliary equipment. The main components of the boiler are: 1. Furnace: fuel burn-up and ensures that the boiler outlet gas temperature to a value of convection heating surface cooled safe work; 2, economizer: utilizing the heat of the flue boiler feedwater heating, to reduce the exhaust gas temperature, fuel economy and functions. 3, the drum: the respective heating surface and joined together and the boiler water wall tubes and other components decreased water circulation circuit. Soda storage drum, can adapt to changes in load, with internal steam separator means to ensure the quality of soft drinks, no DC boiler drum. 4, water wall: mainly radiation heating surface of the boiler, the absorption of radiant heat furnace heated working fluid to protect the furnace wall and the like. 5, combustion equipment: the fuel and air required for combustion of the fuel into the furnace ignition and stable good combustion; 6, air preheater: heating the fuel with air, in order to enhance ignition and combustion; flue gas waste heat absorption, reduced exhaust tobacco temperature, increase boiler efficiency. 7, the furnace walls: a housing to protect the boiler, since sealing and insulation. Heavy furnace wall of the small boiler may also function as a support member boiler. 8, the frame: a support member and the fixing boilers, Purple east 15:33:06 boiler auxiliary equipment are: 1, the wind equipment: induced draft fan and chimney via the flue gas generated in boiler operation sent to the atmosphere. 2, dust removal equipment: removing fly ash in the boiler flue gas. 3, the fuel supply equipment: fuel storage and transportation functions. 4, water supply equipment: water pump water supply through the water into the boiler by the processing device to. 5. Dust Cleaner equipment: removing ash from the boiler and carried away. 6, the blower device: by the air blower after exports the furnace air preheater and a coal grinding device heating applications. 7, the automatic control device: automatic detection, process control, automatic protection and automatic adjustment. IMPORTANT boiler maintenance and a maintenance, water maintenance method 1. The boiler must be a qualified treatment, which is to extend the life of the boiler, ensure the safe operation of the gas and steam. 2. The water temperature should be close to the furnace temperature, preferably above 20 ℃. 3. The need for low-water cutoff periodically inspect maintenance and cleaning. Water Level Controller cleaned at least once a month, rinse water table at least once a day. Rinse water table should be at the highest level; after flushing the water level should not be less than the minimum safe level, not as a net wash, can wash many times, but it must be flushed at the highest level. 4. require periodic blowdown operation, daily (per shift) at least once, after the sewage drain valve should be checked whether the influence by dirt and leaks; if it must be excluded. 5. Shutdown the steam pressure is not maintained, the boiler will produce steam space negative pressure air entrapment, and therefore should rise again to the fire burning total steam valve is opened. 6. smoke tube fouling will lead to increased exhaust gas temperature, so that boiler efficiency is lowered, so that the fuel consumption increases, it should periodically open the front door, brushing or blow smoke tube fouling.

Main 10ton coal fired steam boiler temperature abnormal phenomenon of how to do 1, main steam temperature anomalies alarm. 2, the rapid variation of the main steam temperature, a secondary damper frequently significantly reducing water operation. 3, starting superheat outlet steam separator above or below normal. 4, if the steam with water, the unit will water shock occurs. 1 reason, the fuel and water supply imbalance, the separator outlet temperature abnormality. 2, coal combustion conditions change or affect, such as excessive load lift; and pulverizing mill administration system abnormality stop; means automatically increase or decrease the failure rate is too large amount of wind and the like. 3, the central flame furnace changes, such as the bottom seal damage, W and inadequate flame downstroke. 4, the control failure by warm water, warm water flow rate reduction is abnormally reduced or increased. 5, feedwater temperature mutation. 6, does not match the wind coal. 7, the secondary combustion heating surface. 8, furnace coking or fouling seriously. 9, heating surface leakage squib. 10, flue gas damper opening degree is not normal. 11, coal sudden change occurred. 12, the uniformity of the powder feeding substantial change occurs. 1 process, failure caused by unit coordinated coal - water ratio should be immediately released coordinate offset, in accordance with the current load demand, with reference to the start of the steam superheat separator, and adjusting the amount of fuel corresponding to the amount of water, with one, two main desuperheating water rapidly steam temperature control in a normal range; when the coal - water ratio should avoid imbalance after coal and water while adjusting; when coal - water ratio is adjusted to further adjust the load after a relatively stable; contact maintenance processing timely. 2, when the water supply system fault condition occurs a significant disturbance furnace should pay attention and automatically coordinated working conditions, so as not to manual intervention, when not working properly coordinated and automated, should be manually adjusted, stable water flow, referring to separation according to the water flow steam superheat, the adjusted amount of fuel, with a secondary spray water rapidly controlling the main steam temperature within the normal range; contact maintenance processing timely. 3, due to rapid changes in load caused by the load change rate should be adjusted; load change caused due to protective operation or the like caused by heat load to be quickly adjusted to maintain the boiler pressure of the main steam stability. 4, by warm water automatic dysregulation, should be appropriate Save warm tone is switched to the manual may be an intermediate point of the feedwater control system be corrected for temperature if necessary, or the feedwater to switch control to manual control, due to lower lifting and lowering the load speed to prevent steam temperature, promptly contact a service process. 5, the boiler furnace cause severe fouling and coking of the main steam temperature anomalies can be corrected by an appropriate degree of superheat outlet steam separator start, adjust, and in a timely manner and the furnace heating surface sootblowing. When the platen superheater sootblowing or superheater outlet temperature is still above normal and a secondary reducing water damper fully open, to check the furnace and the combustion air distribution system is normal, the checking process to reduce still overtemperature unit load. 6, flue gas damper adjusted to an appropriate opening degree. 7, if the bottom seal after losing back to normal immediately. 8, to strengthen the turbine expansion, differential expansion, axial displacement of the shaft vibration and bearing temperature monitoring, if abnormal, the process according to the corresponding regulations. 9, after the above measures, if invalid, should immediately drop the load process. 10, in front of the main steam temperature main steam 50 ℃ drastically reduced within 10 minutes, should an emergency stop.

What part of the body including the boiler? What role have? It comprises a crucible and the furnace: a body: refers to a soda boiler system, which is superheated by the reheater water preheating system and a vaporization system composed of dry steam. The role of the high-pressure boiler feedwater heater through the further heating evaporation, for the purpose of blowing rpm turbine to do work. System configuration: economizer, the drum, the downcomer, water wall, superheater, reheater, economizer high pressure heater outlet feedwater is introduced into the economizer, economizer tube within an outer absorber tube gas and fly ash heat, water temperature increases to about 300 ℃ drum water out from the economizer line into the bubble along the top of the boiler disposed outside. Drum lower half of the water, the upper half steam. Unsaturated high pressure drop along the water reaches the bottom of the bubble tube at the bottom of the lower header outside the boiler, a number of pipes mounted in parallel on the bottom of the boiler around the lower header, the furnace by the upward flow of the absorbent in the central flame of the inner tube wall pipe convective heat radiation heat transfer and high temperature flue gas. Since the heat absorption is much less than the water vapor, the water wall within a predetermined vaporization rate can not be greater than 40%, because the working fluid will easily melt late Wall water absorbing tube rupture occurred. Downcomer role is water vapor to the bag waterwall lower header, to establish a water circulation. Wall water in the tank through the second line and then returned to the boiler water wall, the water in the drum is completed, the downcomer, the circulation between the superheater waterwall separated in the steam drum is withdrawn from the top of the drum, laying into the first top ceiling superheater, then through the cladding wall superheater, low temperature superheater, platen superheater, to a high temperature superheater, after reaching the rated temperature of the heating steam turbine into work. After the reheater boiler is also provided with a large reheat means that steam from the high pressure cylinder acting, temperature and pressure of the exhaust gas is reduced, the exhaust gas is heated to a reheater, and then returned to the steam turbine, a low pressure cylinder continues to work. Furnace body: it refers to a boiler furnace combustion system and its role is to heat the fuel combustion in the furnace as much as possible and transfer heat to the working fluid, and the completion of the water wall and economizer water water heated in the tubes, heated in the dry steam superheater and reheater tubes, the air in the air preheater tube heated. The system consists of: a combustor, furnace, air preheater. Production process: raw coal from the coal by the belt conveyor to the higher field position of the coal bin, the bottom of the coal from the coal bin out through the stoker evenly into the ground to a coal mill. Nature of the atmosphere via the air inlet of the blower is arranged in the vertical flue to the boiler air preheater, subjected to heat of the flue gas, flue gas waste heat recovery. About 250 degrees out of hot air into two air preheater from: one directly introduced into the burners of the boiler as secondary combustion air into the furnace; the other can be introduced into the mill inlet for drying, transporting coal, which said primary air portion of hot air. Excellent flow of drying gas and pulverized coal mixture powder consisting of primary air, conveyed via line separator to be coarse coarse separator, the separated coarse powder inlet sending back regrind mill, and eligible powder and primary air mixture into pulverized powder separator, gas separation, the separated coal fines into storage to save it from the powder according to the magnitude of the thermal load of the boiler, the control of coal flow discharged coal warehouse bottom while separated from the fines separator as the primary air pulverized coal power delivery, after the pressing of mill powder mixture with the gas mixture into a fine powder fed again by a burner into the combustion furnace.

The partnership, fast boiler for the user responsible attitude to have left a deep impression on our fireman boiler operation is not very skilled, fast deliberately sent a party of professional and technical personnel for our on-site supervision of installation, commissioning and training to ensure that the latter can operate our good boiler fireman. --customer feedback

Contact

Contact Form

Address

Related Information

3 ton steam boiler coal fired biomass fired - Steam Boiler

8 ton steam boiler coal fired biomass fired. 2017-9-18 · The packaged grate coal fired boiler is designed to a company in Jatim, Indonesia purchased one set of 6 ton coal fired steam boiler from SZL Biomass fired .

Online chat

DZL Series Coal Fired Steam Boiler - SiTong

New type DZL series coal fired steam Boiler is single drum parallel water and fire tube steam boiler,the combustion equipment is chain grate. Both sides of the wall around the furnace are radiation heating surface. Two wings of furnace are convective heating surface. Inside of the drum is threaded pipe convective heating surface.

Online chat

10 ton coal steam boiler -zozen boiler

10 ton coal fired steam boiler Vietnam,coal fired steam Overview Coal fired steam boiler benefits. 1.Coal fired steam boiler manufactured by ZG Boiler is a chain grate type boiler with high efficiency but cost-effective features.. 2.10 ton coal fired steam boiler used in starch factory is to generate high temperature steam for drying and .

Online chat

industrial boiler manufacturer,steam boiler company

DZL Series Coal Fired Chain Grate Steam Boiler----- The new Type water cooling arch DZL two-wings flue series boiler is fast-assembly boiler developed by Zhongding Boiler and Xian Jiaotong University, this is national patent product, and the patent numb 10ton waste heat recovery steam boiler is installed in Xinmi City, the boiler is

Online chat

food industry 10 ton coal fired steam boiler

Coal fired steam boiler 10 ton/hr can generate 10 ton steam per hour to meet the food processing needs. 10 ton coal fired steam boiler for food plant The food plant 10 ton/hr coal fired boiler is a kind of chain grate boiler mixed in the drum in a bunch of threads pipe . Get a quote.

Online chat

compare operating costs of 10 tons oil steam boilers with

2.Calculation of coal consumption of five or 10 tons of coal-fired steam boilers: 10ton coal fired boiler. The heat required by the boiler, divided by the calorific value of the coal, divided by the thermal efficiency of the boiler, is the hourly coal consumption of a 1 ton coal-fired boiler.

Online chat

Industrial steam boiler 1 ton 2 ton 4 ton 6 ton 8 ton 10

About us. Henan Yuanda Boiler Corporation Ltd., established in 1956. We are professional manufacturer and supplier for coal fired boiler,gas fired boiler,biomass fired boiler,wood chip fired boiler,oil fired boiler,steam boiler,fire tube boiler,industrial boilers.We are with over 50 years' experience in boiler design, technique, production, installation and operation.

Online chat

10ton fire tube steam boiler

We are offering 10ton fire tube steam boiler. we are one of the preeminent manufacturers and suppliers of firetube steam boilers, which we are catering parallel to their consistent demand in africa, Asia, etc. our experience of 60 years enables us in serving you better, so that you can experience the after sale satisfaction with us.

Online chat

10 ton coal fired steam boiler price - sport1-harsewinkel.de

10 Ton Coal fired boiler. Steam Boiler For Textile Industry January 11, 2018 January 11, 2018 No Comments on 10 Ton Coal fired boiler. Coal - Wikipedia. Coal is a combustible black or brownish-black sedimentary rock usually occurring in rock strata in layers or veins called coal beds or coal seams. The harder forms Fly ash - WikipediaFly

Online chat

10Ton H Steam Boiler - dermapraxis-frankfurt.de

10 ton h steam boiler | Steam Boiler Produc. Steam Boiler Machine, Wholesale Various High Quality Steam Boiler Machine Products from Global Steam Boiler Machine Suppliers and Steam Boiler Machine Factory,Importer,Exporter at Alibaba.com. 10ton Steam Boiler Coal Fired Tags: 1 Ton Steam BoilerSteam Boiler, Steam Boiler Suppliers and Manufacturers at Alibaba

Online chat

Zozen Steam Boiler

Zozen main products are:gas fired steam boiler,oil fired steam boiler,coal fired steam boiler,biomass fired steam boiler,cfb steam boiler,applied to various industries. ZOZEN is a steam boiler manufacturer in China.

Online chat

parts of a coal boiler - Industrial Oil Boilers Manufacturers

The 6 ton capacity biomass coal fired steam boiler use for dyeing and printing plant in Lebanon. WNS Fire Tube Oil Steam Boilers. The 2 sets of oil fired fire tube 10ton capacity steam boilers use for textile factory in Bangladesh. Water Tube Vertical Oil Steam Boilers.

Online chat

Szl Series Horizontal 10 Ton Coal Fired Boiler

10T SZL Coal-fired Steam Boiler Project _ZOZEN BOILER_WuXi . ZOZEN produced a 10-ton coal-fired steam boiler (SZL10-1.25-AII) for Jiangxi Yanzhongs production of steam in the production process. The user can set different numbers of independent wind bins according to different tonnages. During production, the user. Get a Quote

Online chat

Wuxi Zozen Boilers Co., Ltd

Wuxi Zozen Boilers Co., Ltd is the government designated boilers and pressure vessles manufacturing enterprise. Now Zozen, with eight modern workshops, covers an area of 120, 000 SQM. The annual capacity is over 12, 000 t/h, and the annual output value, 100 million US Dollars.

Online chat

10 Ton Steam Boiler In Pakistan

10 ton boiler for paper making - kawaiitenshi-akitas. lpg fired steam boiler for palm oil making plant. 1tons szs gas hot water boiler in palm oil mill - CFBC . 2019-3-19 · Industrial hot water boiler, boielrapplication, steam boier 10 Ton Coal and Rice Husk Boiler for Paper Steam Line- 10 Ton Coal and Rice HuskRead more 1tons gas steam boiler in palm oil mill.2 ton rice husk fired steam

Online chat

Project